Meterman DM73B
Digital Display Contact AC/DC Voltage/Resistance/
Continuity Tester
The DM73B is a small probe-style multimeter and designed to be used with one hand. This is helpful when measuring in those small hard-to-get-to areas. The DM73B has Data Hold feature that saves the measurement value on the display for later reading. Two probe style tips ship with the unit, ½” and 3” long.
- 600V AC and 600V DC ranges
-
Cat III 300 V safety rated
-
Cat II 600 V safety rated
-
Improved DC basic accuracy 0.5%
-
Resistance to 34 MΩ
-
Continuity beeper
-
Includes alligator clip, ground test lead, three probe tips and installed batteries
-
3400-count digital display plus analog bargraph
-
Auto power off
-
UL 3111-1 listed
Included accessories:
Download Data Sheet
View Optional Accessories
| Specifications |
| DC Voltage |
| Ranges |
340 mV, 3.4, 34, 340 V, 600 V |
| Accuracy |
± (0.5 % rdg + 2 dgt) |
| Resolution |
0.1 mV in 3.4 V range |
| Input Impedance 340 mV range: |
>100 MΩ |
| Input Impedance Other ranges: |
10 MΩ | |
| AC Voltage (50-500 Hz) |
| Ranges |
3.4 V, 34, 340, 600 V |
| Accuracy |
± (1.5 % rdg + 8 dgt) |
| Resolution |
0.1 mV in 3.4 V range |
| Input Impedance |
10 MΩ | |
| Resistance |
| Ranges |
340 Ω , 3.4, 34, 340 kΩ , 3.4, 34 MΩ |
| Accuracy 340 Ω - 340 kΩ: |
± (1.0 % rdg + 4 dgt) |
| Accuracy 3.4 MΩ: |
± (1.5 % rdg + 4 dgt) |
| Accuracy 34 MΩ: |
± (3.0 % rdg + 5 dgt) |
| Max. Open Circuit Voltage 340Ω range: |
1.2 V |
| Max. Open Circuit Voltage All others: |
0.45 V | |
| Diode Test |
| Range |
3.4 V |
| Accuracy |
± (2.0 % rdg + 3 dgt) |
| Short Circuit Current |
1.0 mA |
| Max Open Circuit Voltage |
3.0 VDC |
| Audible Indication |
< 0.2 V | |
| Continuity Test |
| Display Response |
<0.5 s |
| Continuity Threshold |
≤ 35 Ω | |
| Overload Protection |
| DC and AC Voltage |
600 VDC or AC rms |
| Resistance\Continuity\Diode All ranges |
600VDC or VAC rms | |
| General Specifications |
| Display |
|
3-3⁄4-digit LCD, 3400 count | |
| Measuring Rate |
|
| Bargraph |
|
34 segments –updated 20 readings per second | |
| Operating Temperature Range |
|
| Storage Temperature Range |
|
| Environmental |
|
Intended for indoor use, altitude up to 2000 m | |
| Measurement Accuracy |
|
| Batteries |
|
2x LR44, SR44 or S76; Life: 100 hours nominal | |
| Auto Power Off |
|
| Dimensions |
|
| Weight |
|
| Style |
|
| Volts ac/dc |
|
| Current |
|
| Resistance |
|
| Battery Test |
|
| Continuity Beeper |
|
| Special Features |
|
Analog bar graph,Auto Power Off,Data Hold | |
| Safety Ratings |
|
CULUS, CAT III 300 VCAT II 600 V | |
| Warranty |
|
!
<<
|
|