600A AC
4000uA DC
4000 Count Display
600A AC
4000uA DC
1000V DC
40MW
4000uF
Continuity
Temperature
1.3" Jaw Size
The AC75 combines a clamp meter, a multimeter, and a thermometer into one meter. The AC75 is designed for electrical and HVAC work. The AC75 has a Type K digital thermometer, a high capacitance range, and display backlight. The extra features of the AC75 enable more specialized troubleshooting.
-
600 A AC current
-
4000 uA DC current for flame rod testing
-
Measures temperature to 1000 °F (400 °C)
-
Includes Type K thermocouple probe
-
AC/DC 750 V/1000 V
-
40 MΩ resistance
-
Capacitance to 4000 µF for motor capacitance run/start testing
-
Continuity beeper
-
4000-count large digit display
-
Jaw size 35mm (1.3")
-
Auto power off
-
Full overload protection
-
One-year warranty
-
CAT II 1000 V, CAT III 600 V safety rated
Included accessories:
- Test Leads
-
Temperature adapter
-
Type K probe
-
Users manual
-
Carrying case
Download Data Sheet
View Optional Accessories
| Specifications |
| AC A (50/60 Hz) |
| Ranges |
400 A, 600 A |
| Accuracy 0 to 100 A |
± (1.9 % + 2 A) |
| Accuracy 100 to 400 A |
± (1.9 % + 1 A) |
| Accuracy 400 to 600 A |
± (2.5 % + 7 A) |
| Resolution |
0.1A | |
| DC A |
| Ranges |
400, 4000 µA |
| Accuracy |
±(1.0 %+2 d) |
| Resolution |
0.1 µA |
| ACV |
(50 to 500 Hz) |
| Ranges |
4, 40, 400, 750 V |
| Accuracy |
±(1.5 %+5 d) |
| Resolution |
1 mV | |
| DCV |
| Ranges |
4, 40, 400, 1000 V |
| Accuracy |
±(0.9 %+2 d) |
| Resolution |
1 mV | |
| Resistance |
| Ranges |
400, 4 k, 40 k, 400 k, 4 M, 40 MW |
| Accuracy 400W |
±(1.0 % + 2 d) |
| Accuracy 4 kW to 400 kW |
±(0.7 % + 2 d) |
| Accuracy 4 M |
±(1.0 % + 2 d) |
| Accuracy 40 MW |
±(1.5 % + 2 d) |
| Resolution |
0.1 ½ | |
| Diode Test |
| Max test current/Accuracy 1.5 mA |
±(1.5 % + 5 d) |
| Open circuit voltage |
3 V | |
| Continuity Beeper |
| Threshold approx. |
200 ½ |
| Indicator |
2 kHz tone buzzer | |
| Capacitance |
| Ranges |
4 n, 40 n, 400 n, 4 µ, 40 µ, 400 µ, 4 mF |
| Accuracy 4 n |
±(3.0 % + 20 d) |
| Accuracy All other ranges |
±(2.0 % + 8 d) |
| Resolution |
1 pF | |
| Temperature |
| Ranges |
0 °C, 400 °C (32 °F, 750 °F, 1000 °F) |
| Accuracy -40 °C to .1 °C |
±(1 % + 4 °C) |
| Accuracy 0 °C to 400 °C |
±(1 % + 3 °C) |
| Accuracy -40 °F to 32 °F |
±(1 % + 8 °F) |
| Accuracy 32 °F to 750 °F |
±(1 % + 6 °F) |
| Accuracy 750 °F to 1000 °F |
±(2 % + 8 °F) |
| Resolution |
0.1 °C/1 °F | |
| General Specifications |
| Operating temperature |
|
| Maximum jaw opening |
|
| Safety |
|
Designed to meet IEC 1010-1 and IEC 61010-2-032, Class 2 and pollutiondegree 2 indoor use. Complies with CE and CSA 22.2 No. 1010-1 andNo. 1010.2.032 requirements. | |
| Battery life |
|
| Power requirement |
|
Standard 9 V battery NEDA 1604, JIS 006P | |
| Dimensions |
|
84 mm (W) x 212 mm (L) x 40 mm (D) (3.3 x 8.4 x 1.6 inches) | |
| Weight |
|
|