| Specifications |
| DC Voltage |
| Ranges |
600 V |
| Accuracy |
± (0.75 % rdg + 2 dgts) |
| Resolution |
1 V in 600 V range |
| Input Impedance |
10 MΩ | |
| AC Voltage (40-450 Hz) |
| Range |
400 V, 600 V |
| Accuracy |
± (1.2 % rdg + 5 dgts) |
| Resolution |
0.1 V in 400 V range |
| Input Impedance |
10 MΩ | |
| DC Current |
| Ranges |
400 A, 600 A |
| Accuracy |
± (2 % rdg + 5 dgts) |
| Resolution |
0.1 A in 400 A range | |
| AC Current (40-450 Hz) |
| Ranges |
400 A, 600 A |
| Accuracy |
± (2 % rdg + 5 dgts) |
| Resolution |
0.1 A in 400 A range | |
| Frequency (Hz), Current and Voltage |
| Ranges |
4 kHz, 20 kHz |
| Accuracy |
± (0.5 % rdg + 5 dgts) |
| Resolution |
1 Hz in 4 kHz range |
| Sensitivity |
5 A/1 V in 4 kHz range5 A/5 V in 20 kHz range | |
| Resistance |
| Range |
4 kΩ |
| Accuracy |
± ( 1.0 % rdg + 5 dgts) |
| Resolution |
1 Ω in 4 kΩ range |
| Open Circuit Volts |
0.5 V DC |
| Max Short Circuit Current |
0.8 mA | |
| Diode Test |
| Accuracy |
± (1.0 % rdg + 2 dgts) |
| Resolution |
0.001 V |
| Open Circuit Volts |
3.2 V DC |
| Max Short Circuit Current |
0.8 mA | |
| Continuity |
| Range Threshold Tone at 40 Ω |
± 15 Ω |
| Open Circuit Volts |
3.2 V DC |
| Max Short Circuit Current |
0.8 mA | |
| Peak Hold Measurement AC Voltage (40-450 Hz) |
| Range |
400 V, 600 V |
| Accuracy |
± (1.5 % rdg + 10 dgts) |
| Resolution |
0.1 V in 400 V range |
| Input Impedance |
10 MΩ | |
| Peak Hold Measurement AC Current (40-450 Hz) |
| Range |
400 A, 600 A |
| Accuracy |
± (2.0 % rdg + 10 dgts) |
| Resolution |
0.1 A in 400 A range | |
| Overload Protection |
| Voltage |
1000 V DC/750 V AC |
| Current |
800 Amps |
| Resistance |
660 V rms |
| Diode |
660 V rms | |