The AC65 is a True RMS AC clamp multimeter. It measures non-linear load current. The AC65 is designed for electrical contractors, electricians, HVACR installers and servicers, as well as commercial building and industrial plant maintenance personnel and electrical shops.
-
600A, True-rms for non-sinusoidal current
-
AC Voltage to 600V
-
Resistance and Continuity Test
-
Autoranging for fast response time
-
Data Hold button
-
Continuity Beeper
-
Jaw Size 40mm (1.6”)
-
4000-count
-
Carrying case included
-
CAT II 600 V, CAT III 300 V rated
Included accessories:
- Test Leads
- Users manual
-
Carrying case
Download Data Sheet
View Optional Accessories
| Specifications |
| AC Voltage (40-500 Hz) |
| Ranges |
400 V, 600 V |
| Accuracy |
± (1.2 % + 5 dgts) |
| Crest Factor (1.4 to 2.0): |
+ 0.6 % |
| Crest Factor (2.0 to 2.5): |
+ 2.0 % |
| Resolution |
100 mV in 400 V range |
| Input Impedance |
10 MΩ // < 100 pF | |
| AC Current (50-60 Hz) |
| Range |
400 A, 600 A |
| Accuracy 400 A: |
± (l.9 % rdg + 5 dgts) |
| Accuracy 600 A: |
± (2.9 % rdg + 5 dgts) |
| Resolution |
0.1 A in 400 A range |
| AC Conversion Type |
True-rms |
| Crest Factor (1.4 to 2.0): |
+ 1.0 % |
| Crest Factor (2.0 to 2.5): |
+ 2.5 % | |
| Resistance |
| Range |
4 kΩ, 40 kΩ |
| Accuracy |
± (2.0 % rdg + 9 dgts) |
| Resolution |
1 Ω in 4 kΩ range |
| Max Open Circuit Voltage |
1 V | |
| Continuity |
| Buzzer Sounds When resistance is |
< 200 Ω | |
| Overload Protection |
| AC Volts, Resistance |
600 V rms |
| AC Current |
800 A rms | |
| General Specifications |
| Display |
|
33⁄4 digit LCD, max reading of 3999 | |
| Display Update Rate |
|
| Power |
|
Single 9V battery(NEDA 1604, IEC 6F22) | |
| Battery Life: |
|
| Dimensions (WxLxH) |
|
88 x 215 x 36 mm(3.5˝ x 8.5˝ x 1.4˝) | |
| Weight |
|
| Operating Temperature |
|
0 °C to + 45 °C, < 75 % R.H. | |
| Storage Temperature |
|
- 20 °C to + 60 °C < 80 %R.H. | |
| Temperature Coefficient |
|
O.2 x (spec. acc’y) fOC,< 18 °C or > 28 °C | |