Compact true-rms meter for HVAC (heating ventilation air conditioning) troubleshooting. The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.
-
Built-in thermometer for HVAC applications
-
Microamps to test flame sensors
-
Low input impedance: helps prevent false readings due to ghost voltage
-
Large white LED backlight to work in poorly lit areas
-
Resistance, continuity, frequency and capacitance
-
Min/Max/Average with elapsed time to record signal fluctuations
-
Compact ergonomic design for one-handed operation
-
Compatible with optional magnetic hanger (ToolPak™)
-
CAT III 600V safety rated
Included accessories:
Download Datasheet
View Accessories
| Specifications |
| Maximum voltage between any terminal and earth ground |
|
| Surge protection |
|
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 | |
| Display |
| Digital: |
6,000 counts, updates 4 per second | |
| Bar graph |
|
33 segments, updates 32 per second | |
| Operating Temperature |
|
| Storage Temperature |
|
| Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
| Battery Life |
|
400 hours typical, without backlight | |
| Accuracy Specifications |
| DC millivolts |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% of reading] + [counts]): 2.0% + 3 | |
| DC volts |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V | |
| Auto volts |
| Range: |
600.0 V |
| Resolution: |
0.1 V |
| Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) | |
| AC millivolts1 true-rms |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) | |
| AC volts1 true-rms |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) | |
| Continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. | |
| Ohms |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| Accuracy: |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
1.5 % + 2 | |
| Diode Test |
| Range/Resolution: |
2.000 V / 0.001 V |
| Accuracy: |
0.9% + 2 | |
| Capacitance |
| Range/Resolution: |
1000 nF / 1 nF |
| Range/Resolution: |
10.00 μF / 0.01 μF |
| Range/Resolution: |
100.0 μF / 0.1 μF |
| Range/Resolution: |
9999 μF / 1 μF |
| Range/Resolution: |
100 μF to 1000 μF |
| Accuracy: |
1.9% + 2 |
| Range/Resolution: |
> 1000 μF |
| Accuracy: |
5% + 20% | |
| LoZ capacitance |
| Range: |
1 nF to 500 μF |
| Accuracy: |
10% + 2 typical | |
| Temperature2 (Type-K thermocouple) |
| Range/Resolution: |
-40 °C to 400 °C / 0.1 °C |
| Accuracy: |
1% + 102 |
| Range/Resolution: |
-40 °F to 752 °C / 0.2 °F |
| Accuracy: |
1% + 182 | |
| AC μamps true-rms (45 Hz to 500 Hz) |
| Range/Resolution: |
600.0 μA / 0.1 μA |
| Accuracy: |
1.0% + 2 | |
| DC μamps |
| Range/Resolution: |
600.0 μA / 0.1 μA |
| Accuracy: |
1.0% + 2 | |
| Hz (V or A input)2 |
| Range/Resolution: |
99.99 Hz / 0.01 Hz |
| Range/Resolution: |
999.99 Hz / 0.1 Hz |
| Range/Resolution: |
9.999 Hz / 0.001 Hz |
| Range/Resolution: |
50.00 Hz / 0.01 Hz |
| Accuracy: |
0.1% + 2 | |
Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
| Mechanical & General Specifications |
| Size |
| Height: |
27.62 cm (10.875") |
| Length: |
15.875 cm (6.25") |
| Width: |
5.6 cm (2.203") | |
| Weight |
|
| Warranty |
|