Fluke 336
600A AC/DC
True-RMS
600A AC
600A DC
600V AC/DC
6000W
Continuity
Display Hold
Backlight
1.2" Jaw Size
The Fluke 330 Series gives clamp meter a whole new meaning.
-
A True-rms clamp meter that measures ac/dc current and voltage, ohms, motor start-up current with large display and backlight Auto shut-off maximizes battery life so the meter works when you need it
-
Small body and jaws fit perfectly in your hand and into tight places
-
Large, backlit display (on most models) is easy-to-see
-
In-rush current function (on most models) for measuring starting current for motors, lighting, etc.
-
Improved low current measurement accuracy from new microprocessor technology
-
Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch)
-
Handy 'Display Hold' button keeps measurements on the display
-
IEC 1010-2-032, 600V CAT III
Included accessories:
Download Data Sheet
View Optional Accessories
| Specifications |
| Voltage DC |
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts | |
| Voltage AC |
| Fluke 333/334 |
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts (50/60 Hz) |
| AC Response: |
Averaging |
| Fluke 335 |
|
|
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts (50/60 Hz) |
| AC Response: |
True-rms |
|
|
| Fluke 336/337 |
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts (20-100 Hz), 6% ± 5 counts (100-400 Hz) |
| AC Response: |
True-rms | |
| Current DC |
| Fluke 336 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 3 counts |
|
|
| Fluke 337 |
|
| Range: |
0 - 999.9 A |
| Accuracy: |
2% ± 3 counts | |
| Current AC |
| Fluke 333/334 |
|
| Range: |
0 - 400.0 A |
| Accuracy: |
2% ± 5 counts (50/60 Hz) |
| AC Response: |
Averaging |
|
|
| Fluke 335 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 5 counts (50/60 Hz) |
| Crest Factor(50/60 Hz): |
2.4 @ 500A, 2.0 @ 600A, add 2% for CF>2 |
| AC Response: |
True-rms |
|
|
| Fluke 336 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 5 counts (10-100 Hz), 6% ± 5 counts (100 - 400 Hz) |
| Crest Factor(50/60 Hz): |
3 @ 500A, 2.5 @ 600A, add 2% for CF>2 |
| AC Response: |
True-rms |
|
|
| Fluke 337 |
|
| Range: |
0 - 999.9 A |
| Accuracy: |
2% ± 5 counts (10-100 Hz), 6% ± 5 counts (100 - 400 Hz) |
| Crest Factor(50/60 Hz): |
3 @ 500A, 2.5 @ 600A, 1.42@1000 A, add 2% for CF>2 |
| AC Response: |
True-rms | |
| Resistance |
| Fluke 333 |
|
| Range: |
0 - 600.0 Ω |
| Accuracy: |
1.5% ± 5 counts |
|
|
| Fluke 334/335/336/337 |
|
| Range: |
0 - 600.0 Ω, 6001 - 6000 Ω |
| Accuracy: |
1.5% ± 5 counts | |
| Frequency |
| Fluke 337 |
|
| Range: |
5 - 400Hz |
| Accuracy: |
0.5% ± 5 counts |
| Trigger Level: |
10-100 Hz >= 5A, 5-10 Hz, 100-400 Hz >=10A | |
| Inrush Current |
| Fluke 334/335/336/337 |
|
| Integration Time: |
100 ms | |
| Continuity |
|
| MIN/MAX |
|
| Environmental Specifications |
| Operating Temperature |
|
-10 °C to +50 °C, -14 °F to 122 °F | |
| Storage Temperature |
|
-40ºC to +60ºC, -22 °F to 140 °F | |
| Operating Altitude |
|
2,500 meters max, 6,500 ft max | |
| Temperature De-rating |
|
Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC (above 82.4°F or below 64.4°F) | |
| Safety Specifications |
| Safety Rating |
|
IEC 1010-2-032, 600V CAT III | |
| Mechanical & General Specifications |
| Size |
| Fluke 333/334/335 |
|
|
240mm x 80mm x 40mm (9.375" x 3.125" x 1.625") |
|
- |
| Fluke 336/337 |
|
|
250mm x 80mm x 40mm (9.875" x 3.125" x 1.625") | |
| Weight |
|
| Warranty |
|
| Battery Life |
|
Alkaline approximately 150 hours continuous |
|
Automatic low battery indicator | |
| Backlight |
|
| Display Hold |
|
!
<<
|
|