Meterman
!

Meterman AC50

!
Larger picture 

 

AC Low Leakage

 

4000 Count Display

4 Ranges of A AC

400V AC

400W

Continuity

1.2" Jaw Size

 

 

 

AC current measurement to 60 A. Leakage current measurements with resolution of 0.01mA AC voltage to 400V. The AC50 Leakage Current Clamp Multimeter offers 10 microAmp resolution for measuring low AC current. It’s great for applications requiring measurement of leakage and fault currents, and current pick-up of instruments in service and maintenance areas. Plus this versatile unit measures up to 60A AC, AC voltage, resistance and continuity.

 

  • Resistance measurement and continuity beeper
  • Min/Max control to see largest and smallest values in a series of measurements
  • Relative value measurement to determine differentials
  • Data Hold to freeze measurement value on the display
  • Digital display with analog bargraph
  • Jaw opening 30 mm (1.2 inch)
  • Auto-Power-Off to save battery life

Included accessories:

  • Test leads
  • Users manual
  • Carrying case

Download Data Sheet

 

View Optional Accessories

 

 

General Specifications
Display
3-3/4, LCD including functions and symbols, 4000 count
Bar graph
40 segments
Range Selection
Manual
Auto-Power-Off
Approx. 30 min.
Overload Display
The left digit is blinking
Measuring Rate
20 measurements/sec. (bargraph)
2 measurements/sec. (LCD)
Clamp Opening
30 mm
Overvoltage category
CAT II 600 V
Pollution Degree
2
Battery Display
Battery symbol in display at low battery
Power Supply
Battery 1.5 V IEC LR6 (alkaline), 2 each
Current Consumption
Approx. 10 mA
Operating Temperature
-10 °C to 50 °C
Storage Temperature
20 °C to 60 °C with battery removed
Humidity
< 75 % relative humidity
Dimensions
183 x 63.6 x 35.6 mm
Weight
190 g

Measurement Features
Range
Accuracy (50 Hz/60 Hz)
Current ac
40 mA, 400 mA,
4 A, 40 A, 60 A
0 - 40 mA (10 μA resolution) ±(1.5 % rdg. +3 dgt)
40 - 400 mA ±(1.5 % rdg. +3 dgt)
400 mA - 4 A ±(1.5 % rdg. +3 dgt)
4 - 40 A ±(1.5 % rdg. +3 dgt)
40 - 50 A ±(1.5 % rdg. +5 dgt)
50 - 60 A ±(3.0 % rdg. +5 dgt)
Voltage ac
0 to 400 V ±(1.0 % rdg. +3 dgt)
Overload Protection 600 VAC
Resistance
0 to 400 Ω ±(1.0 % rdg. +3 dgt)
Overload Protection 600 VAC
Continuity
< 40 Ω approx
Open Circuit Voltage < 0.4 V
Overload Protection 600 V AC

Meterman AD40A

!
Larger picture 

 

400A AC

 

4000 Count Display

400A AC

1" Jaw Size

 

 

 

 

 

The AD40A is an AC mini-clamp ammeter that measures up to 400A AC in a small space. The AD40A measures low AC current in 40A range. It uses a compact design size to ergonomically fit easily into the hand. Plus its compact size makes it a handy daily tool to fit into the slightest of tool kits. It has an easy to read digital display with Data Hold capabilities and an Analog Bargraph. Plus, you get 10mA resolution when using the 40A range.

 

  • 40 and 400 A AC ranges
  • 10 mA resolution in 40 A range
  • 4000-count display with bar graph
  • Autoranging, Data Hold and Auto-Power Off
  • CAT III 600 V rated

Included accessories:

  • Users manual
  • Carrying case

View Data Sheet

 

View Accessories

 

Specifications
AC Current
Ranges 40 A, 400 A
Accuracy ± (2 % rdg + 10 dgts)
Resolution 0.01 A in 40 A range
Overload Protection
660 A for AC current

General Specifications
Display
3 3⁄4 digit LCD (max reading 3999)
Overrange Indication
“OL” indicated
Low Battery Indication
Battery symbol
Power Supply
Two (2) 1.5 V AAA batteries (UM-4)
Battery Life
Alkaline 300 hours, approx
Maximum Jaw Opening
25.4 mm
Dimensions (WxHxD)
64 x 190 x 36 mm
Weight
250 g (incl. Battery)
Operating Temperature
0 °C to +40 °C, < 80 % R.H. non-condensing
Storage Temperature
-10 °C to +60 °C, < 70 % R.H. non-condensing, batteries removed;

Meterman AC40A

!
Larger picture 

 

400A AC

 

4000 Count Display

400A AC

600V AC/DC

400W

Continuity

1" Jaw Size

 

 

 

The AC40A is a small clamp multimeter that measures up to 400A AC. The AC40A also measures voltage, resistance, continuity, and low AC current in 40 A range. It uses a compact design size to ergonomically fit easily into the hand. Plus its compact size makes it a handy daily tool to fit into the slightest of tool kits. It has an easy to read digital display with Data Hold capabilities and an Analog Bargraph. Plus, you get 10mA resolution when using the 40A range.

 

  • 40 and 400 A ranges
  • 10 mA resolution in 40 A range
  • 600 V AC and DC range
  • Continuity Beeper
  • 4000-count display with bargraph
  • Autoranging, Data Hold and Auto Power Off
  • CAT III 600 V rated

Included accessories:

  • Test Leads
  • Users manual
  • Carrying case

Download Data Sheet

 

View Optional Accessories

 

 

Specifications
DC Voltage
Ranges 400 V, 600 V
Accuracy ± (1.2 % rdg + 5 dgts)
Resolution 0.1 V in 400 V range
Input Impedance 1 MΩ
AC Voltage (50-400 Hz)
Ranges 400 V, 600 V
Accuracy ± (1.5 % rdg + 10 dgts)
Resolution 0.1 V in 400 V range
Input Impedance 1 MΩ
AC Current
Ranges 40 A, 400 A
Accuracy ± (2 % rdg + 10 dgts)
Resolution 0.01 A in 40 A range
Resistance
Range 400 Ω
Accuracy ± (1 % rdg + 5 dgts)
Resolution 0.1 Ω in 400 Ω
Continuity (audible)
Continuous Tone and •))) Display at R < 40 Ω
Max Open Voltage 1.2 V
Overload Protection
660A for AC current only
660V rms for all other measurements

General Specifications
Display
33⁄4 digit LCD (max reading 3999)
Overrange Indication
“OL” indicated
Low Battery Indication
Battery symbol appears when battery power is low
Power Supply
Two (2) 1.5 V AAA batteries (UM-4)
Battery Life
Alkaline 300 hours, approx
Maximum Jaw Opening
25.4 mm
Dimensions (WxHxD)
64 x 190 x 36 mm
Weight
280 g (incl. battery)
Operating Temperature
0 °C to + 40 °C, < 80 % R.H. noncondensing
Storage Temperature
- 10 °C to + 60 °C, < 70 % R.H. non-condensing, batteries removed

Meterman AC60

!
Larger picture 

 

600A AC

 

4000 Count Display

600A AC

600V AC

40kW

Continuity

1.6" Jaw Size

 

 

 

The AC60 is a durable AC clamp multimeter with a safe hand guard design. The AC60 is designed for electrical contractors, electricians, HVACR installers and servicers, as well as commercial building and industrial plant maintenance personnel and electrical shops.

 

  • Professional’s 600 A, AC clamp meter
  • Autoranging for fast response
  • AC voltage to 600V
  • Data Hold button
  • Continuity Beeper
  • Jaw Size 40mm (1.6”)
  • 4000-count
  • Carrying case included
  • CAT II 600 V, CAT III 300 V rated

Included accessories:

  • Test Leads
  • Users manual
  • Carrying case

Download Data Sheet

 

View Optional Accessories

 

 

Specifications
AC Voltage ( 40 – 500 Hz)
Ranges 400 V, 600 V
Accuracy ±(1.2 %+ 5 dgts)
Resolution l00 mV in 400 V range
Input Impedance 10 MΩ // < 100 pF
AC Current (50/60 Hz)
Range 400 A, 600 A
Accuracy 400 A ± (1.9 % rdg + 5 dgts)
Accuracy 600 A ± (2.9 % rdg + 5 dgts)
Resolution 0.1 A in 400 A range
AC Conversion Type Avg. sensing indicating
Resistance
Range 4 kΩ, 40 kΩ
Accuracy ± (2.0 % rdg + 9 dgts)
Resolution 1 Ω in 4 kΩ range
Max Open Circuit Voltage 1 V
Continuity
Buzzer sounds when resistance is < 200 Ω
Overload Protection
AC Volts, Resistance 600 V rms
AC Current 800 A rms

General Specifications
Display
3 3⁄4 Digit LCD, 3999 counts
Display Update Rate
4/sec
Power
Single 9V battery (NEDA 1604,IEC 6F22)
Battery Life
Alkaline 200 hours
Dimensions (WxLxH)
88 x 215 x 36 mm (3.5˝ x 8.5˝ x 1.4˝)
Weight
320 g (11.3 oz)
Operating Temperature
0 °C to +45 °C, < 75 % R.H.
Storage Temperature
-20 °C to +60 °C < 80 % R.H.
Temperature Coefficient
0.2 x (spec. Acc’y)/°C, < 18 °C or >28 °C

Meterman AC65

!
Larger picture 

 

600A AC

 

4000 Count Display

True RMS

600A AC

600V AC

40kW

Continuity

1.6" Jaw Size

 

 

The AC65 is a True RMS AC clamp multimeter. It measures non-linear load current. The AC65 is designed for electrical contractors, electricians, HVACR installers and servicers, as well as commercial building and industrial plant maintenance personnel and electrical shops.

 

  • 600A, True-rms for non-sinusoidal current
  • AC Voltage to 600V
  • Resistance and Continuity Test
  • Autoranging for fast response time
  • Data Hold button
  • Continuity Beeper
  • Jaw Size 40mm (1.6”)
  • 4000-count
  • Carrying case included
  • CAT II 600 V, CAT III 300 V rated

Included accessories:

  • Test Leads
  • Users manual
  • Carrying case

Download Data Sheet

 

View Optional Accessories

 

 

Specifications
AC Voltage (40-500 Hz)
Ranges 400 V, 600 V
Accuracy ± (1.2 % + 5 dgts)
Crest Factor (1.4 to 2.0): + 0.6 %
Crest Factor (2.0 to 2.5): + 2.0 %
Resolution 100 mV in 400 V range
Input Impedance 10 MΩ // < 100 pF
AC Current (50-60 Hz)
Range 400 A, 600 A
Accuracy 400 A: ± (l.9 % rdg + 5 dgts)
Accuracy 600 A: ± (2.9 % rdg + 5 dgts)
Resolution 0.1 A in 400 A range
AC Conversion Type True-rms
Crest Factor (1.4 to 2.0): + 1.0 %
Crest Factor (2.0 to 2.5): + 2.5 %
Resistance
Range 4 kΩ, 40 kΩ
Accuracy ± (2.0 % rdg + 9 dgts)
Resolution 1 Ω in 4 kΩ range
Max Open Circuit Voltage 1 V
Continuity
Buzzer Sounds When resistance is < 200 Ω
Overload Protection
AC Volts, Resistance 600 V rms
AC Current 800 A rms

General Specifications
Display
33⁄4 digit LCD, max reading of 3999
Display Update Rate
4/sec
Power
Single 9V battery(NEDA 1604, IEC 6F22)
Battery Life:
200 hours (Alkaline)
Dimensions (WxLxH)
88 x 215 x 36 mm(3.5˝ x 8.5˝ x 1.4˝)
Weight
320 g (11.3 oz)
Operating Temperature
0 °C to + 45 °C, < 75 % R.H.
Storage Temperature
- 20 °C to + 60 °C < 80 %R.H.
Temperature Coefficient
O.2 x (spec. acc’y) fOC,< 18 °C or > 28 °C

Meterman AC68

!
Larger picture 

 

600A AC/DC

 

4000 Count Display

600A AC/DC

600V AC/DC

40kW

20kHz

Continuity

1.6" Jaw Size

 

 

The AC68 has additional features such as frequency combined with both AC and DC current measurement. The AC68 is designed for electrical contractors, electricians, HVACR installers and servicers, as well as commercial building and industrial plant maintenance personnel and electrical shops.

 

  • AC and DC current to 600A
  • AC and DC voltage to 600V
  • Frequency to 20kHz through the clamp jaws
  • Resistance and Continuity
  • Data Hold and AC Peak
  • DC Amps auto zero
  • Jaw Size 40 mm (1.6”)
  • 4000-count
  • Carrying case included
  • CAT II 600 V, CAT III 300 V rated

Included accessories:

  • Test Leads
  • Users manual
  • Carrying case

Download Data Sheet

 

View Optional Accessories

 

 

Specifications
DC Voltage
Ranges 600 V
Accuracy ± (0.75 % rdg + 2 dgts)
Resolution 1 V in 600 V range
Input Impedance 10 MΩ
AC Voltage (40-450 Hz)
Range 400 V, 600 V
Accuracy ± (1.2 % rdg + 5 dgts)
Resolution 0.1 V in 400 V range
Input Impedance 10 MΩ
DC Current
Ranges 400 A, 600 A
Accuracy ± (2 % rdg + 5 dgts)
Resolution 0.1 A in 400 A range
AC Current (40-450 Hz)
Ranges 400 A, 600 A
Accuracy ± (2 % rdg + 5 dgts)
Resolution 0.1 A in 400 A range
Frequency (Hz), Current and Voltage
Ranges 4 kHz, 20 kHz
Accuracy ± (0.5 % rdg + 5 dgts)
Resolution 1 Hz in 4 kHz range
Sensitivity 5 A/1 V in 4 kHz range5 A/5 V in 20 kHz range
Resistance
Range 4 kΩ
Accuracy ± ( 1.0 % rdg + 5 dgts)
Resolution 1 Ω in 4 kΩ range
Open Circuit Volts 0.5 V DC
Max Short Circuit Current 0.8 mA
Diode Test
Accuracy ± (1.0 % rdg + 2 dgts)
Resolution 0.001 V
Open Circuit Volts 3.2 V DC
Max Short Circuit Current 0.8 mA
Continuity
Range Threshold Tone at 40 Ω ± 15 Ω
Open Circuit Volts 3.2 V DC
Max Short Circuit Current 0.8 mA
Peak Hold Measurement AC Voltage (40-450 Hz)
Range 400 V, 600 V
Accuracy ± (1.5 % rdg + 10 dgts)
Resolution 0.1 V in 400 V range
Input Impedance 10 MΩ
Peak Hold Measurement AC Current (40-450 Hz)
Range 400 A, 600 A
Accuracy ± (2.0 % rdg + 10 dgts)
Resolution 0.1 A in 400 A range
Overload Protection
Voltage 1000 V DC/750 V AC
Current 800 Amps
Resistance 660 V rms
Diode 660 V rms

General Specifications
Display
3 3⁄4 digit, LCD, max reading of 3999
Display Update Rate
2/sec, nominal;
Power
9 V battery(NEDA 1604, IEC 6F22)
Battery Life
200 hours(Alkaline)
Operating Temperature
0 °C to + 40 °C < 80 % R.H.
Storage Temperature
- 10 °C to + 60 °C, < 70 % R.H. non-condensing
Maximum Jaw Opening
40 mm (1.57˝)
Dimensions (WxHxD)
76 x 228 x 39 mm (3˝ x 9˝ x 1.5˝)
Weight (incl. Battery)
465 grams

Meterman AD105

!
Larger picture 

 

1000A AC/DC

 

4000 Count Display

True-RMS

1000A AC/DC

10kHz

2" Jaw Size

 

 

 

 

The AD105 True rms ammeter measures non-linear loads to 1000 Amps. Measures both AC and DC Current. It has the widest range of current measurement of all the Meterman clamp meters. The AD105 is designed for electrical contractors, electricians, HVACR installers and servicers, as well as commercial building and industrial plant maintenance personnel and electrical shops.

 

  • Broad range 1000 A AC and DC
  • True-rms for non-sinusoidal current measurement
  • Frequency to 10kHz
  • Peak Hold and DC Auto Zero
  • Autoranging for fast response time
  • 4000-count
  • Belt-clip sleeve carrying case included
  • CAT III 1000 V rated

Included accessories:

  • Users manual
  • Carrying case

Download Data Sheet

 

View Optional Accessories

 

 

Specifications
AC Current (40-400 Hz)
Ranges 400 A, 1000 A
Accuracy 0 - 40 A ± (1.9 % rdg + 8 dgts)
Accuracy 40 - 400 A ± (1.9 % rdg + 7 dgts)
Accuracy 400 - 1000 A ± (2.9 % rdg + 5 dgts)
Crest Factor (C.F. 1.4 to 2.0) + (1.0 % rgd)
Crest Factor (C.F. 2.0 to 2.5) + (2.5 % rgd)
Crest Factor (C.F. 2.5 to 3.0) + (4.0 % rgd)
Position Error ± (1.0 % rdg)
Resolution 0.1 A in 400 A range
AC Current (Peak Hold)
Ranges Low, High
Accuracy ± (3.0 % rdg + 10 dgts)
Resolution 0.1 A in Low range
DC Current
Ranges 400 A, 1000 A
Accuracy 0 - 100 A ± (2.9 % rdg + 8 dgts)
Accuracy 100 - 400 A ± (1.9 % rdg + 5 dgts)
Accuracy 400 - 1000 A ± (2.9 % rdg + 5 dgts)
Position Error ± (1.0 % rdg)
Resolution 0.1 A in 400 A range
Frequency
Ranges 4 kHz, 10 kHz
Accuracy ± (0.5 % rdg + 3 dgts)
Resolution 1 Hz in 4 kHz range
Min. Input Frequency 20 Hz
Sensitivity < 1 kHz 6 A rms
Sensitivity 1 – 10 kHz 10 A rms

General Specifications
Display
3 3⁄4 digit LCD (max reading 3999)
Display Update Rate
2/sec
Overrange Indication
“OL” indicated
Low Battery Indication
Battery symbol appears when battery power is low
Power Supply
One 9 V battery (NEDA 1604, IEC 6F22)
Battery Life
Alkaline 40 hours, approx.
Maximum Jaw Opening
51 mm
Maximum Conductor Size
51 mm (2 inches)
Operating Temperature
0 °C to +50 °C, < 75 % R.H. non-condensing
Storage Temperature
-20 °C to +60 °C, < 80 % R.H. non-condensing, batteries removed
Temperature Coefficient
0.2 x (Spec. Acc’y), < 18 °C or >28 °C
Dimensions (WxHxD)
240 x 106 x 40 mm
Weight
420 g (incl. Battery)

Meterman AC71

!
Larger picture 

 

600A AC

  

6000 Count Display

600A AC

750V AC

1000V DC

2000W

Continuity

Backlight

1.3" Jaw Size

 

 

The AC71 is an automatic digital clamp multimeter with two additional unique features: AutoTect™ measurement and automatic backlight. The AutoTect™ feature automatically senses what type of measurement is being made when the test leads are placed across a measurement point. The automatic backlight turns itself on when it senses a dim viewing work area.

 

  • AutoTect™ Function – automatically selects ac volts, dc volts or resistance depending upon measurement point
  • Automatic bright blue backlight turns on when a dark environment is sensed
  • Easy one-button control
  • AC current to 600 A
  • AC volts to 750 V
  • DC volts to 1000 V
  • Resistance and Continuity Beeper
  • Data Hold
  • Conductor size 1.25 in, 32 mm, 750 MCM
  • Safety rated to CAT II 1000 V, CAT III 600 V, cCSAus listed

Included accessories:

  • Test Leads
  • Users manual
  • Carrying case

Download Data Sheet

 

View Optional Accessories

 

 

Specifications
Voltage AC (50 to 500 Hz)
Range: 1.3 V to 750.0 V
Accuracy: ±(1.5% + 3 dgt)
Voltage DC
Range: 1.8 V to 1000.0 V
Accuracy: ±(1% + 2 dgt)
Range: -0.6 V to -1000.0 V
Accuracy: ±(1% + 4 dgt)
Overvoltage Protection
Range: 1000 V dc/750 V ac
Input Impedance £
4 k Ω W for input voltage up to 30 V. Impedance increases with input voltage to approximate 300 k Ω at 1000 V/277 k Ω at 750 V ac.
Resistance and continuity
Range: 0.0 Ω to 99.9 Ω
Accuracy: ±(2% + 1 Ω )
Range: 100.0 Ω to 2000 Ω
Accuracy: ±(2% + 2 dgt)
Overload Protection
Range: 1000 V dc / 750 V rms
Maximum Open Circuit Voltage
Range: 1.5 V
Continuity Check
Internal sounds activate if the resistance of the circuit under test is less than 25 Ω. It will then turn off if the resistance is increased beyond 150 Ω.
Temperature coefficient multiply by 1.5 when operating temperature is 40 °C to 50 °C.
AC Current (50 to 60 Hz)
Range: 0.0 to 60.0 A
Accuracy: ±(1.9% + 2 A)
Range: 60.0 to 400.0 A
Accuracy: ±(1.9% + 5 A)
Range: 401 to 500.0
Accuracy: ±(2.5% + 7 A)
Range: 501 to 600.0 A*
Accuracy: ±(3% + 10 A)
Overload Protection
Range: 0 to 500 A: Continuous operation
* 501 A to 600 A: 10 minutes maximum followed by 10 minute cooling period

General Specifications
Display
6000 digit large scale liquid crystal display (LCD)
Measuring Rate
5 times per second
OverRange Display
OL is displayed
Automatic Power Off Time
Approximately 30 minutes after power on
Low Battery Indication
The battery symbol is displayed when the battery voltage drops below the operating level for accurate results.
Power
Single standard 9 V battery, NEDA160A
Battery Life
250 hours with an alkaline 9 V battery
Environmental
Indoor use
Operating Temperature
0 °C to 30 °C at < 80 % R.H.
30 °C to 40 °C at < 75 % R.H.
40 °C to 50 °C at < 45 % R.H.
Storage Temperature
-20 °C to 60 °C at 0 to 80 % R.H. (battery removed)
Altitude
2000 m (6562 ft)
Conductor Size
32 mm diameter (1.3 in)
Max. Operation Time
Delay Time = 30s for input < 30 V
Shock Vibration
Sinusoidal vibration per MIL-PRF-28800F (5 to 55 Hz, 3 G max)
Agency Approvals
CE, cCSAus
Safety
Conforms to EN61010-1:2001; CAT II 1000 V, CAT III 600 V, Pollution degree 2, Class 2
EMC
Conforms to EN61326-1. This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference.

Meterman AC75

!
Larger picture 

 

600A AC

4000uA DC

 

4000 Count Display

600A AC

4000uA DC

1000V DC

40MW

4000uF

Continuity

Temperature

1.3" Jaw Size

 

 

The AC75 combines a clamp meter, a multimeter, and a thermometer into one meter. The AC75 is designed for electrical and HVAC work. The AC75 has a Type K digital thermometer, a high capacitance range, and display backlight. The extra features of the AC75 enable more specialized troubleshooting.

 

  • 600 A AC current
  • 4000 uA DC current for flame rod testing
  • Measures temperature to 1000 °F (400 °C)
  • Includes Type K thermocouple probe
  • AC/DC 750 V/1000 V
  • 40 MΩ resistance
  • Capacitance to 4000 µF for motor capacitance run/start testing
  • Continuity beeper
  • 4000-count large digit display
  • Jaw size 35mm (1.3")
  • Auto power off
  • Full overload protection
  • One-year warranty
  • CAT II 1000 V, CAT III 600 V safety rated

Included accessories:

  • Test Leads
  • Temperature adapter
  • Type K probe
  • Users manual
  • Carrying case

Download Data Sheet

 

View Optional Accessories

 

 

Specifications
AC A (50/60 Hz)
Ranges 400 A, 600 A
Accuracy 0 to 100 A ± (1.9 % + 2 A)
Accuracy 100 to 400 A ± (1.9 % + 1 A)
Accuracy 400 to 600 A ± (2.5 % + 7 A)
Resolution 0.1A
DC A
Ranges 400, 4000 µA
Accuracy ±(1.0 %+2 d)
Resolution 0.1 µA
ACV (50 to 500 Hz)
Ranges 4, 40, 400, 750 V
Accuracy ±(1.5 %+5 d)
Resolution 1 mV
DCV
Ranges 4, 40, 400, 1000 V
Accuracy ±(0.9 %+2 d)
Resolution 1 mV
Resistance
Ranges 400, 4 k, 40 k, 400 k, 4 M, 40 MW
Accuracy 400W ±(1.0 % + 2 d)
Accuracy 4 kW to 400 kW ±(0.7 % + 2 d)
Accuracy 4 M ±(1.0 % + 2 d)
Accuracy 40 MW ±(1.5 % + 2 d)
Resolution 0.1 ½
Diode Test
Max test current/Accuracy 1.5 mA ±(1.5 % + 5 d)
Open circuit voltage 3 V
Continuity Beeper
Threshold approx. 200 ½
Indicator 2 kHz tone buzzer
Capacitance
Ranges 4 n, 40 n, 400 n, 4 µ, 40 µ, 400 µ, 4 mF
Accuracy 4 n ±(3.0 % + 20 d)
Accuracy All other ranges ±(2.0 % + 8 d)
Resolution 1 pF
Temperature
Ranges 0 °C, 400 °C (32 °F, 750 °F, 1000 °F)
Accuracy -40 °C to .1 °C ±(1 % + 4 °C)
Accuracy 0 °C to 400 °C ±(1 % + 3 °C)
Accuracy -40 °F to 32 °F ±(1 % + 8 °F)
Accuracy 32 °F to 750 °F ±(1 % + 6 °F)
Accuracy 750 °F to 1000 °F ±(2 % + 8 °F)
Resolution 0.1 °C/1 °F

General Specifications
Operating temperature
0 °C - 50 °C
Maximum jaw opening
Up to 1.3" (35 mm)
Safety
Designed to meet IEC 1010-1 and IEC 61010-2-032, Class 2 and pollutiondegree 2 indoor use. Complies with CE and CSA 22.2 No. 1010-1 andNo. 1010.2.032 requirements.
Battery life
400 hours (alkaline)
Power requirement
Standard 9 V battery NEDA 1604, JIS 006P
Dimensions
84 mm (W) x 212 mm (L) x 40 mm (D) (3.3 x 8.4 x 1.6 inches)
Weight
Approx. 390 g (15 oz.)